From the study….”Our data confirmed that approximately one in five primary total knee replacement patients were not satisfied with the outcome…”


Despite substantial advances in primary TKA, numerous studies using historic TKA implants suggest only 82% to 89% of primary TKA patients are satisfied. We reexamined this issue to determine if contemporary TKA implants might be associated with improved patient satisfaction. We performed a cross-sectional study of patient satisfaction after 1703 primary TKAs performed in the province of Ontario. Our data confirmed that approximately one in five (19%) primary TKA patients were not satisfied with the outcome. Satisfaction with pain relief varied from 72–86% and with function from 70–84% for specific activities of daily living. The strongest predictors of patient dissatisfaction after primary TKA were expectations not met (10.7× greater risk), a low 1-year WOMAC (2.5× greater risk), preoperative pain at rest (2.4× greater risk) and a postoperative complication requiring hospital readmission (1.9× greater risk).